Textile Machinery Motors (FYQ/FYQQ and FO Series): What Makes Them Different
FYQ/FYQQ vs FO, FO2 and FO3 textile machinery motors from the Red Flag catalogue: starting torque, cooling, enclosure, connection and what to check.

The Red Flag catalogue lists two families of three-phase induction motors for textile machines. FYQ and FYQQ are high-starting-torque motors that start in delta and switch to star after starting, and are cooled by a fan on the frame (IC411). The catalogue names FYQQ as a main motor for air-jet looms. FO, FO2 and FO3 are textile motors listed with different cooling codes (IC0041 for FO and FO2, IC410 for FO3, which ABB describes as totally enclosed without a fan), and the catalogue describes FO2 as resisting fibre clogging. All five are listed as IP44 in the catalogue; the series text gives S1 duty for FYQ, FO, FO2 and FO3, and 50 Hz for FYQ, FYQQ, FO and FO3.
When you replace a motor on a textile machine, match the series and model on the nameplate first, then check power, voltage and frequency, connection, cooling, enclosure and mounting against the machine and motor drawings.
What are the FYQ and FYQQ series?
The catalogue groups them as "FYQ, FYQQ 3-phase induction motors for textile machines". What it states:
| Item | FYQ | FYQQ |
|---|---|---|
| Type (catalogue wording) | High-starting-torque three-phase induction motor | Enclosed, self-cooled squirrel-cage three-phase induction motor with higher starting torque and good low-frequency characteristics |
| Application stated | Textile machines | Main motor for air-jet looms; suited to impact loads |
| Duty | S1 (continuous) | Not stated in the series text |
| Insulation | Class B | Not stated in the series text |
| Enclosure | IP44 | IP44 |
| Cooling | IC411 | IC411 |
| Mounting | IM B3 | Not stated in the series text |
| Supply | 50 Hz, 380 V | 50 Hz |
| Connection | Delta at start, star after starting | Delta at start, star after starting |
The catalogue also says FYQQ motors save electricity compared with general motors where the load includes impacts. That is the manufacturer's description; it does not give a test method or figure for it, so treat it as a description, not a specification.
What are the FO, FO2 and FO3 series?
The catalogue groups them as "FO, FO2, FO3 3-phase induction motors for textile machines":
| Item | FO | FO2 | FO3 |
|---|---|---|---|
| Application stated | Textile machines | Cotton, wool, linen, silk and chemical-fibre textile machines; especially short-fibre environments | Cotton, wool, linen, silk and chemical-fibre textile machines |
| Feature stated | — | Better resistance to fibre clogging than a general motor; higher overload capability | — |
| Duty | S1 | S1 | S1 |
| Insulation | Not stated | Not stated | Class B |
| Enclosure | IP44 | IP44 | IP44 |
| Cooling | IC0041 | IC0041 | IC410 |
| Mounting | IM B3 | IM B3; other arrangements on request | Not stated in the series text |
| Supply and connection | 50 Hz, 380 V, star | Not stated in the series text | 50 Hz, 380 V, star (4-pole of FO3-41-4/16 in delta); other voltages and frequencies on request |
Cells marked "not stated" are not stated in the series text, not a claim that the motor lacks them. Ask for the catalogue page of the exact model.
What do the codes in these tables mean?
Each code follows a published convention. ABB's Low Voltage Motors – Motor Guide (2019) explains them for its own motors:
- S1. "Continuous running duty: Operation on constant load of sufficient duration for thermal equilibrium to be reached."
- Class B insulation. ABB lists "Thermal class 130 (B)".
- IP44. The first digit 4 means "protected against solid objects greater than 1 mm"; the second digit 4 means "protected against splashing water."
- IC410 and IC411. ABB says the cooling designation "is based on the standard IEC 60034-6" and gives "IC 410: totally enclosed motors without a fan" and "IC 411: totally enclosed standard motors, frame-surface cooled with a fan."
- IC0041. ABB's list doesn't include this code. Read it against IEC 60034-6, or ask us to confirm with the factory what it means for the model you need.
For more on enclosure codes, see IP protection ratings explained. For mounting, see mounting codes IM B3, B5, B14 and B35.
So what actually separates the two families?
Putting the catalogue text side by side, three differences stand out:
- Starting. FYQ and FYQQ are described as high-starting-torque motors and start in delta, then switch to star. FO and FO3 are listed in star connection (one FO3 model's 4-pole winding in delta).
- Cooling. FYQ and FYQQ are IC411, which ABB describes as frame-surface cooled with a fan. FO3 is IC410, described by ABB as without a fan; FO and FO2 are IC0041.
- Stated use. FYQQ is named for air-jet looms. FO2 is named for short-fibre environments and fibre-clogging resistance. FO3 is named for cotton, wool, linen, silk and chemical-fibre machines.
Which one a given machine needs is decided by the machine maker's drawing and the original motor's nameplate, not by the series description.
What should I send when I need a replacement?
Send a photo of the old nameplate and these details:
- Series and model (for example an FO2 or FYQQ model number).
- Power, poles and speed.
- Voltage, frequency and connection shown on the nameplate.
- Cooling and enclosure codes.
- Mounting arrangement and shaft dimensions, or the machine drawing.
- Quantity.
We check them with the factory. Wiring and connection changes should follow the motor nameplate and the machine maker's instructions; see reading a star-delta motor nameplate.
A note on standards: China has textile industry standards for some of these series, such as FZ/T 99003 for FO-series motors and FZ/T 99005 for JFO2 and FO2 series. We have not reviewed their full text, and the catalogue does not state which standard each series is built to. Ask us if your buyer needs that confirmed.
FAQ
Is an FO motor the same as an FYQ motor?
No. In the catalogue, FYQ is a high-starting-torque motor with fan cooling (IC411) that starts in delta; FO is listed in star connection with cooling code IC0041.
Which series is meant for air-jet looms?
The catalogue names FYQQ as a main motor for air-jet looms.
Can these motors run on 60 Hz or another voltage?
The series text lists 50 Hz for FYQ, FYQQ, FO and FO3, and 380 V for FYQ, FO and FO3. For FO3 it says other frequencies and voltages can be made on request. Ask us per model.
What are your MOQ and lead time?
MOQ, lead time and payment terms depend on the motor model. Send your requirements.
Ask for a textile motor quote
Shawn is an authorized export sales agent for Red Flag Motor (Qingdao Tianyi Group Red Flag Motor Co., Ltd., founded in 1976). See our motors or contact us with your nameplate photo. We usually reply within one working day (GMT+8).
Sources
| Source | What it supports | Checked |
|---|---|---|
| Red Flag Motor catalogue, pp. 15–17 (FYQ, FYQQ, FO, FO2, FO3 series text) | Series descriptions, duty, insulation, enclosure, cooling, mounting, supply and connection | 2026-11-24 |
| ABB — Low voltage motors: Motor guide (2019), pp. 23, 24, 34, 46 | IC 410 / IC 411 per IEC 60034-6; IP digits; thermal class 130 (B); S1 duty | 2026-11-24 |
| ChineseStandard.net — FZ/T 99003-1992 | Standard title and scope summary for textile FO-series motors | 2026-11-24 |
| ChineseStandard.net — FZ/T 99005-1992 | Standard title for textile JFO2 and FO2 series motors | 2026-11-24 |