Back to all articles
TechnicalNovember 6, 20266 min read

Motor Mounting Codes IM B3, B5, B14 and B35: Which One Do You Need?

What IEC 60034-7 mounting codes IM B3, B5, B14 and B35 mean, how foot and flange mountings differ, and how to tell which one your machine needs.

Four simplified side views of a horizontal motor: IM B3 with feet, IM B5 with a large flange and through bolts, IM B14 with a small face flange and threaded holes, and IM B35 with feet and a large flange

IM B3, B5, B14 and B35 are mounting codes from IEC 60034-7. They describe how a motor is fixed to a machine. IM B3 is a foot-mounted motor. IM B5 has a large flange with clearance holes. IM B14 has a smaller face flange with tapped holes. IM B35 has both feet and a B5 flange. The code you need is the one that matches how your machine holds the motor. Take it from the machine drawing or the nameplate of the motor you are replacing.

This guide explains what the codes mean, how they map to the numeric IM codes, and what to send when you ask for a quote.

What is the IM code in IEC 60034-7?

IEC 60034-7 "specifies the IM Code, a classification of types of construction, mounting arrangements and the terminal box position of rotating electrical machines". The current edition is the third, IEC 60034-7:2020.

The standard separates two ideas:

  • Type of construction: the "arrangement of machine components with regard to fixings, bearing arrangement and shaft extension".
  • Mounting arrangement: the "orientation on site of the machine as the whole with regard to shaft alignment and position of fixings".

In practice, "B3" tells you both: the motor has feet (construction), and it sits on them with the shaft horizontal (mounting arrangement).

Why do some catalogues write IM B3 and others IM 1001?

They are the same thing in two systems. IEC 60034-7 provides "Code I", an alphanumeric designation "applicable to machines with end-shield bearing(s) and only one shaft extension", and "Code II", an all-numeric designation for a wider range of machines. Annex A of the standard gives the relationship between them.

The pairs below are from ABB's general performance motor catalogue (2010), used here as an example of how a motor maker writes them:

Code ICode IIWhat it is (ABB catalogue wording)
IM B3IM 1001Foot-mounted motor
IM B5IM 3001Flange-mounted motor, large flange with clearance holes
IM B14IM 3601Flange-mounted motor, small flange with tapped holes
IM B35IM 2001Foot- and flange-mounted, IEC flange (B35 "from B3")
IM B34IM 2101Foot- and flange-mounted, IEC flange (B34 "from B3")

Source: ABB, Low voltage General performance motors catalogue, EN 02-2010, pp. 11–12.

B5 or B14: how are the two flanges different?

Both are flange mountings, but they bolt on differently. ABB's catalogue describes B5 as a "large flange with clearance holes" and B14 as a "small flange with tapped holes". With B5, the bolts pass through the flange. With B14, the bolts screw into threads in the motor's face.

The size difference can be large on the same frame. In ABB's 2010 catalogue, for frame 90:

Mounting (ABB, frame 90)Pitch circle M (mm)Spigot N (mm)Outer P (mm)Holes S
IM 3001, IM B516513020012 mm clearance
IM 3601, IM B1411595140M8 thread

Source: ABB, Low voltage General performance motors catalogue, EN 02-2010, p. 12. These are ABB's dimensions, shown as an example only. Check the drawing of the motor you are buying.

Front views of two flanges for an IEC frame 90 motor from ABB's catalogue: a B5 flange 200 mm across with a 165 mm pitch circle and clearance holes, and a smaller B14 face 140 mm across with a 115 mm pitch circle and M8 threaded holes

So "a flange motor, frame 90" is not enough information. In ABB's example, a B14 motor would not bolt into a machine built for its B5 flange, or the other way round.

When is B35 the right choice?

B35 is a motor with feet and a B5 flange at the same time. ABB's catalogue lists it as an option on a foot-mounted motor: "IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3)". B34 is the same idea with the smaller B14 face.

You need B35 when your machine uses both: the flange locates the motor on the driven equipment, and the feet sit on a base. If your old motor has feet and a flange, and both are bolted in place, it is likely B35 or B34. Check the nameplate or drawing to see which one.

How do I tell which mounting my machine needs?

Check these in order:

  1. The old motor's nameplate or the machine drawing. If it shows an IM code (B3, IM 1001, B35 and so on), use that code.
  2. Feet: does the motor stand on feet bolted to a base or rail? If yes, it includes B3.
  3. Flange: is the motor bolted to the machine by a flange at the shaft end? Look at the holes. Holes the bolts pass through point to B5. Threaded holes in the motor face point to B14.
  4. Both: feet and a flange both bolted means B35 (with B5) or B34 (with B14).
  5. Shaft direction: if the shaft points up or down, the motor is in a vertical arrangement. IEC 60034-7 has a separate relationship table for machines with vertical shafts. Send us the code from the nameplate.
  6. Flange dimensions: measure the pitch circle, spigot and outer diameter, and count the holes. Compare them with the drawing of the new motor.

Mounting is only one part of a direct replacement. The shaft height, shaft size, key and fixing holes must match too. Our guide to IEC motor frame sizes and shaft height explains those checks.

Does a non-standard mounting position change the motor?

It can. ABB's 2010 catalogue has a variant code for motors "modified for non-standard mounting position", which "must be ordered for all mounting arrangements excluding IM B3 (1001), IM B5 (3001), IM B35 (2001), B34 (2101) & B14 (3601)". In other words, at least for that maker, a position outside the common five is an order option, not something to assume.

The same applies when you order from us. Tell us the exact code and position, and we confirm with the factory what that model needs. This guide does not cover changing a motor's mounting on site. If your drawing calls for a different construction, order a motor built for it.

What to send for a quote

  • Power (kW), voltage and frequency, poles or speed
  • Mounting code (for example IM B3, IM B5, IM B14, IM B35, or a vertical code), and shaft direction if vertical
  • Frame size and shaft diameter and length, if you are replacing an old motor
  • For flange motors: pitch circle, spigot, outer diameter, number of holes, and whether the holes are threaded or clear
  • A nameplate photo or the machine drawing

Red Flag motors are made by Qingdao Tianyi Group Red Flag Motor Co., Ltd. in Qingdao. The YTE mounting arrangement is described with IEC 60034-7 codes; check the dimensional drawing for the exact model in the quotation. We confirm the mounting, model, MOQ and lead time with the factory for each enquiry.

FAQ

What is the difference between IM B3 and IM 1001?

None. They are two names for the same foot-mounted construction: B3 is the alphanumeric Code I of IEC 60034-7, and 1001 is the numeric Code II.

Can a B5 motor replace a B14 motor?

Not directly. In ABB's catalogue, B5 is a large flange with clearance holes and B14 a small flange with tapped holes. For frame 90, ABB's B5 flange has a 165 mm pitch circle and its B14 face 115 mm, so the bolt patterns do not match.

What does B35 mean on a motor?

A motor with feet and a B5 flange. ABB's catalogue describes IM 2001 (B35) as foot and flange mounted, made "from B3".

Where do I find the mounting code on my old motor?

Look on the nameplate first, then on the machine or motor drawing. If neither shows it, send us photos of the feet, the flange face and the holes, and we will check with the factory.

Do you supply vertical motors?

Send the vertical mounting code you need, and we will confirm with the factory whether the model is available in that arrangement.

Ask for a motor quote

Shawn is an authorized export sales agent for Red Flag Motor. Send your power, voltage, frequency and mounting code, and we will check them with the factory. Browse Red Flag three-phase motors, read how to read a motor nameplate, or contact us.

Sources

SourceURLChecked
EVS (Estonian Centre for Standardisation and Accreditation), IEC 60034-7:2020 store page: scope ("specifies the IM Code…"); Code I and Code II; third edition replaces 1992 editionhttps://www.evs.ee/en/iec-60034-7-20202026-11-07
VDE Verlag, IEC 60034-7:2020 free preview: Scope; definitions 3.1 "type of construction" and 3.2 "mounting arrangement"; Annex A tables (Code I / Code II; horizontal and vertical shafts)https://assets.vde-verlag.de/iec-normen/preview-pdf/info_iec60034-7%7Bed3.0%7Db.pdf2026-11-07
ABB, Low voltage General performance motors catalogue, EN 02-2010: mounting codes and options (pp. 11–12); B5 "large flange with clearance holes", B14 "small flange with tapped holes"; frame 90 flange dimensions; variant for non-standard mounting positionhttps://library.e.abb.com/public/7b37518ea1d0cb94c1257b130056f26d/General%20performance%20motors%20EN%2002_2010.pdf2026-11-07