IEC Motor Frame Sizes: Shaft Height and Interchangeability
What an IEC frame number such as 90L or 132M tells you, why shaft height alone does not make two motors interchangeable, and what else to measure.

When an old motor fails, the first thing most people read off the nameplate is the power. The second is often the frame size: 90L, 112M, 132S. It looks like a promise that any motor with the same frame will drop straight in.
It is a good starting point, but not a guarantee. This guide explains what an IEC frame number means, where the dimensions come from, and the checks you still need before you order a replacement.
The standard behind IEC frame sizes
IEC frame sizes come from IEC 60072-1, "Rotating electrical machines – Dimensions and output series – Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080". The current, seventh edition was published in 2022 and replaced the 1991 edition.
According to the standard's published scope, it covers:
- foot-mounted machines with shaft heights from 56 mm to 400 mm;
- flange-mounted machines with flange pitch circle diameters from 55 mm to 1 080 mm.
The 2022 edition was "completely revised on the basis of EN 50347" and integrates "the relationships between frame size, shaft extensions, rated outputs and flange numbers". The full tables are in the paid standard, which we have not reproduced here.
What the frame number tells you
The number is the shaft height
For a foot-mounted motor, the shaft height (H) is the distance from the bottom of the feet to the centre of the shaft. In IEC frame designations, the number is that height in millimetres. ABB's IEC dimension chart shows it directly: frame 80 has H = 80 mm, frame 112 has H = 112 mm, frame 132 has H = 132 mm.
So a frame 112 motor puts its shaft centre 112 mm above its mounting surface. A frame 100 motor puts it 12 mm lower. That alone is enough to misalign a coupling or a belt drive.
The letter is the foot length
The letters S, M and L after the number mark shorter and longer versions of the same frame. In ABB's chart, the difference shows up in the spacing of the foot holes along the motor:
| Frame | H (mm) | Shaft D × E (mm) | Foot hole spacing B (mm) |
|---|---|---|---|
| 90S | 90 | 24 × 50 | 100 |
| 90L | 90 | 24 × 50 | 125 |
Source: ABB, IEC Motor Dimensions chart. D is shaft diameter, E is shaft extension length, B is the distance between foot holes along the motor.
A 90S and a 90L have the same shaft height and the same shaft, but the foot-hole spacing along the motor changes from 100 mm to 125 mm, a 25 mm difference. Some charts give two B values for one frame. ABB lists frame 132 with B = 140 mm and B1 = 178 mm, for the shorter and longer variants.
Same frame, different motor: the checks that matter
The frame number fixes the shaft height. Everything else has to be compared separately. Before you treat a new motor as a direct replacement, check these against the old motor or its drawing.
1. Shaft diameter and length
The shaft has to fit the pulley, coupling or gearbox you already have. In ABB's chart the shaft grows with frame size, for example:
| Frame | Shaft D × E (mm) |
|---|---|
| 80 | 19 × 40 |
| 90 | 24 × 50 |
| 100 and 112 | 28 × 60 |
| 132 | 38 × 80 |
Source: ABB, IEC Motor Dimensions chart.
Measure the old shaft. Do not assume the new one matches because the frame does, and check the dimension drawing of the exact motor you are offered.
2. Key and keyway
Check the key width and keyway on the shaft against the bore of your pulley or coupling.
3. Feet and fixing holes
Compare the foot hole spacing across the motor (A) and along it (B), and the hole size, with your base. The letter after the frame number is your first clue.
4. Flange, if there is one
A flange-mounted motor is located by its flange, not its feet. Flange sizes are a separate series in IEC 60072-1, and a frame can come with more than one flange. ABB's chart, for example, lists a B5 flange and a smaller B14 face for frame 80 (pitch circle 165 mm and 100 mm). Check the pitch circle diameter, spigot diameter, number and size of holes, and whether the holes are threaded or clear.
5. Overall length and terminal box
The total length, the fan cover and the position of the terminal box can clash with guards or nearby parts, even when the mounting holes line up.
6. Electrical data
A motor that fits mechanically still has to match the job: rated power, voltage and frequency, number of poles or speed, duty type, efficiency class and protection rating. Read these from the old nameplate. Our guide to reading a motor nameplate explains each field.
Only when all six match can you call the new motor a direct replacement. If one does not match, it may still work, but with a new pulley, adapter plate or base, and that is a decision for the person who installs it.
How to ask for a replacement
Send us:
- A clear photo of the old nameplate.
- The frame size and mounting (feet, flange or both).
- Shaft diameter and length, and the flange details if there is one.
- Foot hole spacing, if the motor is foot-mounted.
- Anything that limits length or terminal box position.
We will match it against the Red Flag range, including IEC aluminium-frame motors, and send the dimension drawing of the proposed motor so you can compare it before you order. MOQ, lead time and payment terms depend on the motor model. Certificate copies are available on request.
FAQ
What does 90L mean on a motor?
90 is the IEC frame number, which is the shaft height in millimetres for a foot-mounted motor. L marks the longer foot length of that frame, compared with 90S.
Are all frame 112 motors interchangeable?
Not automatically. They share a shaft height of 112 mm, but you still need to compare the shaft, key, fixing holes, flange and electrical data.
Is an IEC frame size the same as a NEMA frame size?
No. They are different systems. This article covers IEC frames only.
Where can I find the dimensions for a specific motor?
In the dimension drawing or catalogue from the maker of that motor. IEC 60072-1 sets the series, but always check the drawing for the motor you are buying.
Send us your old nameplate
Tell us what you are replacing and we will check it with the factory. See our general-purpose industrial motors, read how to choose an electric motor, or contact us. Shawn is an authorized export sales agent for Qingdao Tianyi Group Red Flag Motor Co., Ltd.
Sources
| Source | URL | Checked |
|---|---|---|
| IEC 60072-1:2022, scope and edition note (shaft heights 56–400 mm; flange PCD 55–1 080 mm; 7th edition replaces 1991; revised on the basis of EN 50347; relationships between frame size, shaft extensions, rated outputs and flange numbers), via Estonian Centre for Standardisation and Accreditation (EVS) store page | https://www.evs.ee/en/iec-60072-1-2022 | 20261105 |
| ABB, IEC Motor Dimensions chart (IEC Poster): frames 80, 90S, 90L, 100, 112, 132 — H, D, E, B, B1; frame 80 B5 / B14 flange M | https://library.e.abb.com/public/03f0a0cfc65f46dfa71209e0120ffbf9/IEC%20Poster_24x36.pdf | 20261105 |